• -35%
Honeywell VSN-RP1R-PLUS2 VSN-RP1R + Extinction Center
search
  • Honeywell VSN-RP1R-PLUS2 VSN-RP1R + Extinction Center

Morley VSN-RP1R-PLUS2 Extinction center.

Extinction center. Fire detection and extinction control panel controlled by a double microprocessor with redundancy, with a history of the last 450 events. It has system status indicator LEDs and a two-digit discharge time display and incorporates a manual extinguishing button, a gas triggered…

star star star star star
€907.31 €1,395.87 Save 35%
Tax included
Reference VSN-RP1R-PLUS2
Brand Morley
Quantity
Available in 24/48h

Free shipping
Honeywell VSN-RP1R-PLUS2 VSN-RP1R + Extinction Center

Morley VSN-RP1R-PLUS2 Extinction center.

€907.31 €1,395.87 Save 35%

Extinction center. Fire detection and extinction control panel controlled by a double microprocessor with redundancy, with a history of the last 450 events. It has system status indicator LEDs and a two-digit discharge time display and incorporates a manual extinguishing button, a gas triggered sign and a key for selecting manual, automatic or out of service mode.. . Fully programmable: waiting and pause times, discharge timing, cross zone, extinction sequence, etc. It incorporates input circuits for conventional detectors, input for stop or wait button, manual button, monitoring devices such as pressure switch, low pressure, open doors and mechanical override... . It has output circuits for the indication of the different stages of the system, siren output with three stages: alert, alarm, and extinction, gas triggered sign, double extinction circuit and circuits for closing gates and signaling the status of the system. .. . Optionally, it allows the following modules to be connected: an ITAC module, an RS232 VSN-232 card and an Ethernet IP TG-IP-1 card. Cabin with capacity for 2 batteries up to 7A.. . Does not include batteries. . • Supply voltage: 230Vac +- 15% 50/60Hz. • Standby consumption at 24Vdc: 140mA (Without battery charger or external equipment). • Consumption in Alarm at 24Vdc: 380mA (Without battery charger or external equipment. • Zones: 3 zones for detection and configurable coincidence activation. • Power supply: 28.5V/ 2.4A. • Battery charger 28, 5V 260mA max.. • Maximum siren output current: 2 x 250mA (Supervision by diode or 4K7?) • Maximum auxiliary power supply current: 2 x 250mA (fixed and resettable) • Maximum extinction line current: 1Amp • Display: 2 digits x 7 segments • Indication LEDs: 38 for rapid identification of the event • Outputs: 2 Extinction outputs Supervised by diode or 6K8? • Inputs: 7 input circuits for stop, trip, and technical extinction signals Supervision 4.7µF or 6K8? • Relays: 7 NO output circuits for operating mode and general status and extinction 1Amax.. • Siren output: 2 Supervised Diode or 4K7? (500 mA max. each) • End of line of zone: 47 µF or 4K7? • Digital Input: Configurable System Reset, Evacuation, Silence or On/Off Delay • Port tos: 2 RS232 (TTL Rx,Tx,Gnd), 1 I2C (Aux.Modules), 1 USB (Type B). • Internal history: Last 450 events. • Equipment environmental classification: Class A. • Temp. operation: -5ºC to 40ºC. • Operating humidity: 5% to 95% RH without condensation. • Cabin: IP30. Steel chassis with plastic casing and cover: 4Kg (without batteries) 9.3 Kg (with 7Ah batteries). • Dimensions in mm: 381 width 353 height 123 depth. • Approved according to: EN54/2, EN54/4 and EN-12094-1. • CPD Certificate: 1134-CPD-045

Morley

Summary

0

star_border star_border star_border star_border star_border

0 Reviews

Only users who already bought the product can add review.

Write your review

monetization_on Write your review and get voucher for discount 3%
*valid for 60 days

No customer reviews for the moment.