There are no more items in your cart

search
Uni-Trend MT-DATA-UT181A - True RMS Datalogging Multimeter, PC connection for…
True RMS Datalogging Multimeter - PC connection for data dump - AC/DC measurement: to 1000V and 10A - Resistance, capacitance, conductance measurement - Measurement of frequency, temperature, continuity - Data logging and visualization
star
star
star
star
star
Reference
MT-DATA-UT181A
- UNI-T
- Datalogging multimeter CAT III 100V/ CATIV 600V
- LCD display up to 6000 accounts
- DC and AC voltage measurement up to 1000 V
- DC and AC current measurement up to 10 A
- High accuracy in AC with built-in True RMS function
- Resistance, capacitance, conductance, frequency and temperature measurement
- Buzzer for continuity test
- Diode test
- Logging function for up to 20000 datasets and visualization for trend tracking
- Automatic shutdown
- PC connection for data dump.
Features
- True RMS Datalogging Multimeter
- PC connection for data dump
- AC/DC measurement: to 1000V and 10A
- Resistance, capacitance, conductance measurement
- Measurement of frequency, temperature, continuity
- Data logging and visualization
Specs
Brand | Uni-T |
Measuring range DC and AC voltage | DC 1000V ±(0.025%+5) AC 1000V ±(0.3%+30); Frequency of response: 40~500Hz |
DC and AC current measuring range | DC 10A ±(0.08%+10) AC 10A ±(0.6%+20); Frequency of response: 40~500Hz |
Resistance measuring range | 60MΩ ±(0.05%+2) |
Capacitance measuring range | 60mF ±(2%+5) |
Frequency measurement range | 10Hz~60MHz ±(0.01%+5) |
Temperature measurement range | -40°C~1000°C ±(1%+30) |
Display accounts | Up to 60000 |
Auto Range / Manual Range / True RMS | Yes, it has |
Bandwidth | 100 kHz |
Relative mode | Yes, it is available |
Data logging | 20000 |
Continuity test | Yes, it is available |
Low pass filter | 1 kHz |
Diode test | Up to 3V |
Dual temperature measurement | T1, T2, T1-T2, T2-T1 |
Input protection | Yes, it is available |
DC input impedance | ≥10MΩ |
Power | Lithium Battery 2200 mAh 7.4V |
Dimensions | 195 (H) x 95 (W) x 58 (D) mm |
Weight | 638.6 g |
Security | CAT III 100V/ CATIV 600V CATIV [%VAR%] |
Package content
- Digital multimeter
- Test leads
- Temperature probe
- User instructions
- Adapter and power cable
- USB Cable
- CD PC Software
Data sheet
- Weight
- 638.6 g
- Power
- Lithium Battery 2200 mAh 7.4V
Lithium Battery 2200 mAh 7.4V - Dimensions
- 195 (Al) x 95 (An) x 58 (Fo) mm
195 (H) x 95 (L) x 58 (Pr) mm
195 (H) x 95 (W) x 58 (D) mm
195 (H) x 95 (W) x 58 (D) mm - Power supply
- Batterie lithium 2200 mAh 7.4V
- Bandwidth
- 100 kHz
- Consumption
- Batería Litio 2200 mAh 7.4V
- Security
- CAT III 100V/ CATIV 600V
CAT III 100V/ CATIV 600V CATIV [%VAR%]
CAT III 100V/ CATIV 600V CATIV [%VAR%] - Temperature measurement range
- -40°,C~1000°,C ±,(1%+30)
-40°C~1000°C ±(1%+30) - Brand
- Uni-T
- Rango de medida de resistencia
- 60MΩ ±(0.05%+2)
- Rango de medida de capacitancia
- 60mF ±(2%+5)
- Rango de medida de frecuencia
- 10Hz~60MHz ±(0.01%+5)
- Cuentas display
- Hasta 60000
- Auto Rango / Rango manual / True RMS
- Sí dispone
- Test de diodos
- Hasta 3V
- Modo relativo
- Si dispone
- Test de continuidad
- Si dispone
- Protección de entrada
- Si dispone
- Rango de medida de intensidad DC y AC
- DC 10A ±(0.08%+10) AC 10A ±(0.6%+20), Frecuencia de respuesta: 40~500Hz
- Resistance measuring range
- 60M&Omega, ±,(0.05%+2)
60MΩ ±(0.05%+2) - Capacitance measuring range
- 60mF ±,(2%+5)
60mF ±(2%+5) - Frequency measurement range
- 10Hz~60MHz ±,(0.01%+5)
10Hz~60MHz ±(0.01%+5)
10Hz~60MHz ±(0.01%+5) - Display accounts
- Up to 60000
Up to 60000 - Auto Range / Manual Range / True RMS
- Yes, it has
- Diode test
- Up to 3V
- Relative mode
- Yes, it is available
- Continuity test
- Yes, it is available
- Input protection
- Yes, it is available
- Measuring range DC and AC voltage
- DC 1000V ±,(0.025%+5) AC 1000V ±,(0.3%+30), Frequency of response: 40~500Hz
DC 1000V ±(0.025%+5) AC 1000V ±(0.3%+30), Frequency of response: 40~500Hz - DC and AC current measuring range
- DC 10A ±,(0.08%+10) AC 10A ±,(0.6%+20), Frequency of response: 40~500Hz
DC 10A ±(0.08%+10) AC 10A ±(0.6%+20), Frequency of response: 40~500Hz - Rango de medida voltaje DC y AC
- DC 1000V ±(0.025%+5) AC 1000V ±(0.3%+30), Frecuencia de respuesta: 40~500Hz
- Impedancia de entrada DC
- ≥10MΩ
- Registro de datos
- 20000
- Filtro de paso bajo
- 1 kHz
- Medición de temperatura dual
- T1, T2, T1-T2, T2-T1
- DC input impedance
- &ge,10M&Omega,
≥10MΩ
≥10MΩ - Data logging
- 20000
20000 - Low pass filter
- 1 kHz
1 kHz - Dual temperature measurement
- T1, T2, T1-T2, T2-T1
T1, T2, T1-T2, T2-T1 - Plage de mesure de la tension DC et AC
- DC 1000V ±(0.025%+5) AC 1000V ±(0.3%+30), Fréquence de réponse: 40~500Hz
- Gamme de mesure des courants continus et alternatifs
- DC 10A ±(0.08%+10) AC 10A ±(0.6%+20), Fréquence de réponse: 40~500Hz
- Plage de mesure de résistance
- 60MΩ ±(0.05%+2)
- Plage de mesure de la capacité
- 60mF ±(2%+5)
- Plage de mesure de fréquence
- 10Hz~60MHz ±(0.01%+5)
- Affichage comptes
- Jusqu\'à 60000
- Plage automatique / Plage manuelle / True RMS
- Oui
- Mode relatif
- Dispose
- Enregistrement des données
- 20000
- Test de continuité
- Dispose
- Filtre passe-bas
- 1 kHz
- Test des diodes
- Jusqu\'à 3V
- Double mesure de la température
- T1, T2, T1-T2, T2-T1
- Protection d\'entrée
- Dispose
- Impédance d\'entrée DC
- ≥10MΩ
Summary
0
0 Reviews
Only users who already bought the product can add review.
No customer reviews for the moment.